Home » Respina Prouducts » Flame Detector » Laser PLUS VESDA Smoke Detector Model VLP-002
Laser PLUS VESDA Smoke Detector Model VLP-002
- Advanced Laser Technology: Ensures highly accurate and reliable smoke detection.
- Wide Sensitivity Range: Detects smoke concentrations from 0.005 to 20% obs/m.
- Four Adjustable Alarm Levels: Includes Alert, Action, Fire 1, and Fire 2 for tailored alerts.
- High-Efficiency Air Sampling: Draws air through high-efficiency sampling pipes for effective monitoring.
- Airflow Supervision: Each of the four input pipes has sensors to monitor airflow changes.
- Two-Stage Air Filter: Provides ultra-clean air to protect the optical surfaces from contamination.
- Seven Programmable Relays: Allows integration with auxiliary equipment like alarms and strobe lights.
- Modular Design: Facilitates easy maintenance and event reporting for versatile applications.
Description
Rapid and Reliable Smoke Detection with Laser PLUS VESDA
The Laser PLUS VESDA smoke detector, like all VESDA products, is designed to detect fires at the earliest possible stage, providing accurate and reliable smoke density measurements from very low to very high concentrations.
Product Specifications
The Laser PLUS VESDA smoke detector model VLP-002 features a global sensitivity range from 0.005 to 20% obs/m. It supports four adjustable alarm levels (Alert, Action, Fire 1, and Fire 2) and covers an area of up to 2000 square meters.
Advanced Operation of the VESDA VLP-002 Smoke Detector
In the Laser PLUS VESDA smoke detector model VLP-002, air is drawn into the detector through high-efficiency sampling pipes by an aspirator. Each input pipe is equipped with an airflow sensor that monitors changes in airflow. After passing through the device, the air may be returned to the protected area.
Inside the detector, the air passes through a two-stage air filter before reaching the laser detection chamber. The first stage removes dust and contaminants from the sampled air, while the second stage provides ultra-clean air to protect the optical surfaces within the detector.
The detection chamber utilizes a stable Class 1 laser light source and precise positioning sensors to ensure optimal response to different types of smoke.
Laser PLUS Technology for Optimal Performance
The Laser PLUS technology employs unique software tools for environmental monitoring. The AutoLearn feature evaluates the environment and optimizes alarm thresholds during the setup process to provide the earliest possible warning of potential fires without triggering false alarms.
Key Features and Technical Specifications
Wide Sensitivity Range
The VLP-002 can detect smoke concentrations ranging from 0.005 to 20% obs/m, ensuring reliable detection across a broad spectrum of smoke densities.
Laser-Based Smoke Detection
Utilizes a laser for detecting smoke particles in the air, providing high accuracy and reliability.
Four Adjustable Alarm Levels
Features four adjustable alarm levels to suit specific application needs.
High-Efficiency Air Sampling
Employs a high-efficiency air sampling method to gather air from the protected area.
Four Input Pipes
Equipped with four input pipes, allowing it to cover a large area effectively.
Airflow Supervision for Each Sampling Pipe
Each sampling pipe has an airflow supervisor that monitors airflow changes within the pipes.
Optical Protection from Clean Air Barrier
Uses an optical protection system to shield the optics from contamination by dust and other pollutants.
Easy-to-Replace Air Filter
The air filter is designed for easy replacement.
Seven Programmable Relays
Comes with seven programmable relays for activating auxiliary equipment like alarms and strobe lights.
Modular Design and Event Reporting
The VLP-002’s modular design and event reporting capabilities make it a versatile and efficient choice for various applications.
Pricing and Purchase
For pricing and free technical consultation, contact our experts at RESPINA TRADE. You can also request the product catalog via the link below.
In summary, the Laser PLUS VESDA smoke detector model VLP-002 offers rapid and reliable smoke detection with advanced features and high sensitivity. Its robust technology and customizable alarm levels make it an excellent choice for comprehensive fire protection in large areas.
FAQs:
- What is the Laser PLUS VESDA VLP-002 smoke detector? The VLP-002 is a high-sensitivity smoke detector using laser technology to detect smoke at various concentrations, ensuring early fire detection.
- What is the sensitivity range of the VLP-002? The VLP-002 has a global sensitivity range from 0.005 to 20% obs/m, allowing for accurate detection across a wide spectrum of smoke densities.
- How does the VLP-002 ensure reliable smoke detection? It uses laser-based detection with precise positioning sensors and a two-stage air filter to provide accurate and reliable smoke detection.
- What are the alarm levels available on the VLP-002? The VLP-002 supports four adjustable alarm levels: Alert, Action, Fire 1, and Fire 2, customizable to specific application needs.
At Respinatrade, we pride ourselves on being a leading supplier of high-quality equipment for various industries, including oil, gas, steel, cement, and food.
For more information about our certifications and to learn more about our company, please download and open the attached HTML file. It provides a comprehensive overview of our offerings and achievements.
We look forward to the opportunity to work together and support your business with our extensive range of solutions.
Reviews
There are no reviews yet.
Curated for You
DETCON IR-700 Gas Detector
Honeywell Series 3000 MkII Gas Detector
Honeywell Toxic Gas Detector Model 3000 MkII
Honeywell XNX Explosion-Proof Gas Detector
Available Part Numbers:
-
XNX-AMSI-NNNNN
-
XNX-AMSV-NNCB1
-
XNX-AMSE-NNNN
- XNX Honeywell Gas Detector Price : USD 1,400.00 Typical market price – please contact us for latest stock & shipping quote: [email protected]
Oldham OLCT IR Gas Detector
PrimaX MSA IR Gas Detector
- Standards: Compliant with EN 60079-0:2009, EN 60079-1:2007, IEC 60079-31:2009, EN 60079-29-1:2007, EN 50271:2010, and CE EMC Directive: 2014/30/EU.
- Explosion Protection: Rated II 2 G Ex d IIC T4 Gb for gas environments and II 2 D Ex tb IIIC T130° Db for dust environments.
- Ingress Protection: IP67 rated for dust and water resistance.
- Redundancy: Offers 100% redundancy with the failure of the 1st source.
- HART Compatibility: Supports HART 7.0 communication protocol for seamless integration.
Recent Posts
- Open Path vs Point Gas Detectors in Refineries: Which One Is Right for Your Facility?
- How Honeywell’s AI-Driven Building Automation Is Redefining Safety in Smart Facilities
- Fast, Failsafe, Field-Proven: How the Searchpoint Optima Plus Gas Detector Reduces Downtime & Maintenance
- Why Regular Fire Alarm Testing is Crucial
- Purpose Of Fire Detection And Alarm System

Reviews
There are no reviews yet.