Manual Call Point
Alarm and Flasher SF-523J with Special Features
AUTRONICA BF-502/EX Manual Call Point
BG2E (R) Manual Call Point MEDC
Explosion-Proof Flasher XB11 MEDC
Explosion-Proof Siren and Flasher Y07C/C by Clifford & Snell
Explosion-Proof Sounder Beacon CU1-S by MEDC
MEDC BGW-DC Explosion-Proof Fire Alarm Call Point
MEDC BGW-DC NON-CODED EX Fire Alarm Call Point
MEDC DB3B Sounder Range
MEDC SM87HXB Explosion-Proof Beacon
- Certifications: Zone 1 and Zone 2
- Materials: Stainless steel, marine-grade alloy
- Output: 5-joule LED lamp
- Voltage Options: 24V DC, 110V AC, 240V AC
- Ingress Protection: IP66 and IP67
- Temperature Range: -55°C to +70°C (up to 85°C for high-temp variant)
- Lens Colors: Red, amber, green, blue, clear
- Additional Features: Optional lens guard, telephone/relay initiation
MEDC XB15 Flasher
Fire Alarm Call Points or manual call point
Fire alarm call points, also known as manual call point, are essential components in fire alarm and fire and gas detection systems. This article provides a comprehensive overview of these devices, including their applications, installation methods, and importance in safety.
Importance of Fire Alarm Call Points
- Immediate Notification: One prominent feature of fire alarm call points is the immediate notification to individuals present at the location. By pressing the call point button, an urgent signal is sent to the fire alarm system, prompting immediate interaction with fire suppression units.
- Prevention of Fire Spread: Fire alarm call points allow individuals to quickly take necessary actions to control the fire in emergency situations. This vital tool is effective in preventing the spread of fire and reducing damages.
Installation of Fire Alarm Call Points
- Choosing the Suitable Location: Optimal performance of fire alarm call points relies on selecting the appropriate location. These devices should be installed in places where individuals can easily access them. Additionally, they should be placed strategically in significant areas of buildings.
- Conducting Periodic Tests: After installation, periodic testing of call points is essential. Ensure that the device is functioning correctly and any technical issues are addressed. This practice increases confidence in the device’s operation and ensures system safety.
Key Considerations in Selecting the Best Fire Alarm Call Points
- Adherence to Standards: When choosing a fire alarm call point, pay special attention to standards. Ensure that the selected device complies with safety and quality standards.
- Notification Capability: Fire alarm call points should have the capability for immediate and timely notification. This feature assures individuals that the system will operate correctly in the event of a fire, promptly informing them.
Types of Fire Alarm Call Points
In today’s advanced world, call points are available in various types with unique features:
- Break Glass Call Points: These call points feature a breakable glass window, allowing individuals to press the button and trigger the fire alarm. They are typically installed in areas requiring urgency, such as exits or designated pathways.
- Resettable Call Points: Resettable call points have the capability to return to their original state after activation.
- Waterproof Fire Alarm Call Points: Waterproof fire alarm call points are suitable for environments with moisture or water conditions. Using water-resistant materials, these call points function effectively in harsh environmental conditions, ensuring system reliability.
- Explosion-Proof Call Points: Explosion-proof fire alarm call points are equipped with special technologies for use in hazardous environments prone to explosions. They utilize specific materials and technologies to prevent the risk of explosion and maintain safety in hazardous environments.
Best Brands of Fire Alarm Call Points
Reputable brands such as AUTRONICA and MEDC are well-known for their fire alarm equipment:
- AUTRONICA: A Norwegian company specializing in the production of fire alarm and industrial safety control equipment. AUTRONICA is recognized as a pioneer in safety technologies, offering a diverse range of products.
- MEDC: A British company engaged in the manufacture of fire alarm and fire suppression equipment. MEDC specializes in producing devices and accessories related to fire suppression and alarm incidents.
Factors Affecting the Price of manual call point and Sounders
The prices of manual call point and sounders are influenced by several factors, including:
- Technology and Quality: Utilizing advanced technology and high-quality materials in manufacturing can increase the price of manual call point and sounders. Devices made from premium materials and incorporating innovative technologies typically incur higher production costs.
- Raw Materials: The type of materials used in the production of manual call point and sounders plays a crucial role in pricing. High-quality and durable materials often result in higher costs.
- Features and Specifications: The features and additional capabilities of manual call point and sounders can significantly impact their price. Devices with smart features or advanced functionalities may be priced higher than basic models.
- Standards and Certifications: manual call point and sounders that comply with safety standards and regulations are usually preferred. Achieving compliance may require specific tests and certifications, which can increase production costs and subsequently the price of the devices.
- Brand: The brand of manual call point and sounders can also affect pricing. Products from well-known and reputable companies may command higher prices due to brand reputation and perceived quality.
- Order Volume: The volume of orders can play a role in determining the price of manual call point and sounders. Larger orders may allow manufacturers to offer discounts or reduce unit costs through economies of scale.
- Market and Competition: Market conditions and the presence of competitors can also influence pricing. Increased competition may lead to price reductions as manufacturers strive to capture market share.
- After-Sales Services: After-sales services, including warranties, support, and maintenance, can also impact the pricing of manual call point and sounders. Companies offering comprehensive after-sales services may price their products higher to cover the cost of these services.
The combination of these factors contributes to the final pricing of manual call point and sounders. Considering these factors and their implications can help consumers make informed decisions when purchasing these critical safety devices. If you need to purchase various types of manual call point and sounders, contact our experts today for assistance.